Files
EHS-Sentinel-Addon_for_Home…/ressources/dashboard.yaml
echoDaveD 86ef22006d Feature/v0.3.0 (#11)
v0.3.0 - 2025-02-27
Added poller functionality. EHS-Sentinel can now actively request values via Modbus

fetch_intervals and groups can be defined in the config file
default group and pollers are in the sampelconfig
[!CAUTION]
This functionality requires that EHS-Sentinel actively communicates with
the Samsung EHS, so EHS-Sentinel intervenes here in the Modbus data
traffic between the components (it sends its own messages).
The activation of this functionality is exclusively at your own risk.
I assume no liability for any damage caused.

added a homeassistant dashboard.yaml with default Dashboard

edited Measurement

ENUM_IN_FSV_5061 add enums
ENUM_IN_FSV_5094 correct enum values
ENUM_IN_PV_CONTACT_STATE correct enum values
added units for multiple Measurements
Rename some Measurements:

NASA_INDOOR_COOL_MAX_SETTEMP_WATEROUT -> VAR_IN_FSV_1011
NASA_INDOOR_COOL_MIN_SETTEMP_WATEROUT -> VAR_IN_FSV_1012
NASA_INDOOR_COOL_MAX_SETTEMP_ROOM -> VAR_IN_FSV_1021
NASA_INDOOR_COOL_MIN_SETTEMP_ROOM -> VAR_IN_FSV_1022
NASA_INDOOR_HEAT_MAX_SETTEMP_WATEROUT -> VAR_IN_FSV_1031
NASA_INDOOR_HEAT_MIN_SETTEMP_WATEROUT -> VAR_IN_FSV_1032
NASA_INDOOR_HEAT_MAX_SETTEMP_ROOM -> VAR_IN_FSV_1041
NASA_INDOOR_HEAT_MIN_SETTEMP_ROOM -> VAR_IN_FSV_1042
NASA_DHW_MAX_SETTEMPLIMIT -> VAR_IN_FSV_1051
NASA_DHW_MIN_SETTEMPLIMIT -> VAR_IN_FSV_1052
NASA_USE_DHW_THERMOSTAT -> ENUM_IN_FSV_3061
NASA_USE_BOOSTER_HEATER -> ENUM_IN_FSV_3031
NASA_ENABLE_DHW -> ENUM_IN_FSV_3011
NASA_USE_THERMOSTAT!1 -> ENUM_IN_FSV_2091
NASA_USE_THERMOSTAT2 -> ENUM_IN_FSV_2092
Fixes #9
2025-02-27 22:04:27 +01:00

443 lines
20 KiB
YAML

views:
- title: Overview
type: sections
max_columns: 4
subview: false
sections:
- type: grid
cards:
- type: tile
name: Operation mode
vertical: true
hide_state: false
show_entity_picture: false
grid_options:
columns: 6
rows: 2
entity: sensor.samsung_ehssentinel_outdooroperationstatus
- type: tile
entity: binary_sensor.samsung_ehssentinel_controlsilence
name: Silent Mode
vertical: true
hide_state: false
show_entity_picture: false
- type: tile
name: DHW Power
vertical: true
hide_state: false
show_entity_picture: false
entity: binary_sensor.samsung_ehssentinel_dhwpower
grid_options:
columns: 6
rows: 2
- type: tile
name: Defrost Status
vertical: true
hide_state: false
show_entity_picture: false
entity: sensor.samsung_ehssentinel_outdoordefroststep
- type: entities
entities:
- entity: sensor.samsung_ehssentinel_ehssentinelheatoutput
name: Heat Output
secondary_info: last-updated
icon: mdi:heat-wave
- entity: sensor.samsung_ehssentinel_ingeneratedpowerlastminute
name: Generated Power Last Minute
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_ehssentinelcop
name: COP
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_outdoortw1temp
name: Return Temperature
secondary_info: last-updated
icon: mdi:waves-arrow-left
- entity: sensor.samsung_ehssentinel_outdoortw2temp
name: Flow Temperature
secondary_info: last-updated
icon: mdi:waves-arrow-right
- entity: sensor.samsung_ehssentinel_indoordhwcurrenttemp
name: DHW Tank Temperature
secondary_info: last-updated
icon: mdi:water-boiler
- entity: sensor.samsung_ehssentinel_outdoorouttemp
secondary_info: last-updated
name: Outdoor Temperatur
- entity: sensor.samsung_ehssentinel_outdoorcomp1targethz
name: Compressor Frequence
secondary_info: last-updated
icon: mdi:sine-wave
title: Current Data
- type: entities
entities:
- entity: sensor.samsung_ehssentinel_intotalgeneratedpower
name: Total Generated Heat Output
secondary_info: last-updated
icon: mdi:heat-wave
- entity: sensor.samsung_ehssentinel_outdoorcontrolwattmeterallunitaccum
name: Total Consumed Power
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_ehssentineltotalcop
name: Total COP
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_inminutessinceinstallation
name: Total Minutes Since Installation
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_inminutesactive
name: Total Minutes Active
secondary_info: last-updated
title: Life Cycle Data
- type: grid
cards:
- type: history-graph
entities:
- entity: sensor.samsung_ehssentinel_outdoorcomp1orderhz
name: Compressor freq.
- entity: sensor.samsung_ehssentinel_outdoorfanrpm1
name: Outdoor FAN Speed
logarithmic_scale: false
title: Outdoor Unit
hours_to_show: 6
grid_options:
columns: full
rows: 10
- type: history-graph
entities:
- entity: sensor.samsung_ehssentinel_outdoortw1temp
name: Return Temperature
- entity: sensor.samsung_ehssentinel_outdoortw2temp
name: Flow Temperature
logarithmic_scale: false
hours_to_show: 6
grid_options:
columns: full
rows: 10
title: Water Law
- type: history-graph
entities:
- entity: sensor.samsung_ehssentinel_ehssentinelheatoutput
name: Heat Output
- entity: sensor.samsung_ehssentinel_outdoorcontrolwattmeterallunit
name: Power Input
- entity: sensor.samsung_ehssentinel_ehssentinelcop
name: COP
logarithmic_scale: false
hours_to_show: 6
grid_options:
columns: full
rows: 16
title: Efficiency
column_span: 3
- type: sections
max_columns: 5
title: Field Setting Value
path: field-setting-value
sections:
- type: grid
cards:
- type: entities
entities:
- entity: sensor.samsung_ehssentinel_infsv1011
name: Water Out Temp. for Cooling Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv1012
name: Water Out Temp. for Cooling Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv1021
name: Room Temp. for Cooling Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv1022
name: Room Temp. for Cooling Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv1031
name: Water Out Temp. for Heating Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv1032
name: Water Out Temp. for Heating Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv1041
name: Room Temp. for Heating Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv1042
name: Room Temp. for Heating Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv1051
name: DHW tank Temp. Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv1052
name: DHW tank Temp. Min.
secondary_info: last-updated
title: FSV 10** - Remote Controller
show_header_toggle: false
state_color: false
column_span: 1
- type: grid
cards:
- type: entities
entities:
- entity: sensor.samsung_ehssentinel_infsv2011
name: Heating Outdoor Temp. for WL Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2012
name: Heating Outdoor Temp. for WL Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2021
name: Heating Water out Temp. UFH/WL1 Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2022
name: Heating Water out Temp. UFH/WL1 Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2031
name: Heating Water out Temp. FCU/WL2 Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2032
name: Heating Water out Temp. FCU/WL2 Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2041
name: Heating WL Selection
icon: mdi:heating-coil
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2051
name: Cooling Outdoor Temp. for WL Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2052
name: Cooling Outdoor Temp. for WL Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2061
name: Cooling Water out Temp UFH/WL1 Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2062
name: Cooling Water out Temp. UFH/WL1 Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2071
name: Cooling Water out Temp. FCU/WL2 Max.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2072
name: Cooling Water out Temp. FCU/WL2 Min.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2081
name: Cooling WL Selection
secondary_info: last-updated
icon: mdi:snowflake
- entity: sensor.samsung_ehssentinel_infsv2091
name: External Room Thermostat UFH
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv2092
name: External Room Thermostat FCU
secondary_info: last-updated
title: FSV 20** - Water Law
- type: grid
cards:
- type: entities
entities:
- entity: sensor.samsung_ehssentinel_infsv3011
secondary_info: last-updated
name: DHW Application
icon: mdi:water-boiler
- entity: sensor.samsung_ehssentinel_infsv3021
secondary_info: last-updated
name: Heat Pump Max. Temperature
- entity: sensor.samsung_ehssentinel_infsv3022
name: Heat Pump Stop
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3023
name: Heat Pump Start
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3024
name: Heat Pump Min. Space heating operation time
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3025
name: Heat Pump Max. DHW operation time
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3026
name: Heat Pump Max. Space heating operation time
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3032
name: Booster Heat Delay Time
secondary_info: last-updated
- entity: binary_sensor.samsung_ehssentinel_infsv3041
name: Disinfection Application
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3042
name: Disinfection Interval
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3043
name: Disinfection Start Time
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3044
name: Disinfection Target Temp.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3045
name: Disinfection Duration
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3046
name: Disinfection Max Time
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3051
name: Forced DHW Operation Time OFF Function
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3052
name: Farced DHW Operation Time Duration
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3061
name: Solar Panel/DHW Thermostat H/P Combination
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3071
name: Direction of 3Way Valve DHW Tank
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3081
name: Energy Metering BUH 1 step capacity
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3082
name: Energy Metering BUH 2 step capacity
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv3083
name: Energy Metering BSH capacity
secondary_info: last-updated
title: FSV 30** - DHW code
- type: grid
cards:
- type: entities
entities:
- entity: sensor.samsung_ehssentinel_infsv4011
secondary_info: last-updated
name: Heat Pump Heating/DHW Priority
- entity: sensor.samsung_ehssentinel_infsv4012
name: Heat Pump Outdoor Temp. for Priority
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4013
name: Heat Pump Heat OFF
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4021
name: Backup Heater Application
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4022
name: Backup Heater BUH/BSH Priority
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4023
name: Backup Heater Cold Weather Compensation
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4024
name: Backup Heater Threshold Temp.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4025
name: Backup Heater Defrost Backup Temp.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4031
name: Backup Boiler Application
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4032
name: Backup Boiler Boiler Priority
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4033
name: Backup Boiler Threshold Power
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4041
name: Mixing Valve Application
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4042
name: Mixing Valve Target △T (Heating)
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4043
secondary_info: last-updated
name: Mixing Valve Target △T (Cooling)
- entity: sensor.samsung_ehssentinel_infsv4044
name: Mixing Valve Control Factor
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4045
name: Mixing Valve Control Factor
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4046
name: Mixing Valve Running Time
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4051
name: Inverter Pump Application
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4052
name: Inverter Pump Target △T
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4053
name: Inverter Pump Control Factor
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv4061
name: Zone Control Application
secondary_info: last-updated
title: FSV 40** - Heating code
state_color: false
- type: grid
cards:
- type: entities
entities:
- entity: sensor.samsung_ehssentinel_infsv5011
secondary_info: last-updated
name: Outing Mode Water Out Temp. for Cooling
- entity: sensor.samsung_ehssentinel_infsv5012
name: Outing Mode Room Temp. for Cooling
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5013
name: Outing Mode Water Out Temp. for Heating
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5014
name: Outing Mode Room Temp. for Heating
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5015
name: Outing Mode Auto Cooling WL1 Temp.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5016
name: Outing Mode Auto Cooling WL2 Temp.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5017
name: Outing Mode Auto Heating WL1 Temp.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5018
name: Outing Mode Auto Heating WL2 Temp.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5019
name: Outing Mode Target Tank Temp.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5021
name: DHW Saving Temp.
secondary_info: last-updated
- entity: binary_sensor.samsung_ehssentinel_infsv5022
name: DHW Saving Mode
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5023
name: DHW Saving Thermo on Temp.
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5041
name: Power Peak Control Application
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5042
name: Power Peak Control Select Forced Off Parts
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5043
name: Power Peak Control Using Input Voltage
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5051
name: Frequency Ratio Control
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5081
name: PV Control Application
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5082
name: PV Control Setting Temp. Shift Value (Cool)
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5083
name: PV Control Setting Temp. Shift Value (Heat)
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5091
name: Smart Grid Control Application
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5092
name: Smart Grid Control Setting Temp. Shift Value (Heat)
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5093
name: Smart Grid Control Setting Temp. Shift Value (DHW)
secondary_info: last-updated
- entity: sensor.samsung_ehssentinel_infsv5094
name: Smart Grid Control DHW Mode
secondary_info: last-updated
title: FSV 50** - Others code
cards: []
dense_section_placement: true