Feature/v0.3.0 (#11)
v0.3.0 - 2025-02-27 Added poller functionality. EHS-Sentinel can now actively request values via Modbus fetch_intervals and groups can be defined in the config file default group and pollers are in the sampelconfig [!CAUTION] This functionality requires that EHS-Sentinel actively communicates with the Samsung EHS, so EHS-Sentinel intervenes here in the Modbus data traffic between the components (it sends its own messages). The activation of this functionality is exclusively at your own risk. I assume no liability for any damage caused. added a homeassistant dashboard.yaml with default Dashboard edited Measurement ENUM_IN_FSV_5061 add enums ENUM_IN_FSV_5094 correct enum values ENUM_IN_PV_CONTACT_STATE correct enum values added units for multiple Measurements Rename some Measurements: NASA_INDOOR_COOL_MAX_SETTEMP_WATEROUT -> VAR_IN_FSV_1011 NASA_INDOOR_COOL_MIN_SETTEMP_WATEROUT -> VAR_IN_FSV_1012 NASA_INDOOR_COOL_MAX_SETTEMP_ROOM -> VAR_IN_FSV_1021 NASA_INDOOR_COOL_MIN_SETTEMP_ROOM -> VAR_IN_FSV_1022 NASA_INDOOR_HEAT_MAX_SETTEMP_WATEROUT -> VAR_IN_FSV_1031 NASA_INDOOR_HEAT_MIN_SETTEMP_WATEROUT -> VAR_IN_FSV_1032 NASA_INDOOR_HEAT_MAX_SETTEMP_ROOM -> VAR_IN_FSV_1041 NASA_INDOOR_HEAT_MIN_SETTEMP_ROOM -> VAR_IN_FSV_1042 NASA_DHW_MAX_SETTEMPLIMIT -> VAR_IN_FSV_1051 NASA_DHW_MIN_SETTEMPLIMIT -> VAR_IN_FSV_1052 NASA_USE_DHW_THERMOSTAT -> ENUM_IN_FSV_3061 NASA_USE_BOOSTER_HEATER -> ENUM_IN_FSV_3031 NASA_ENABLE_DHW -> ENUM_IN_FSV_3011 NASA_USE_THERMOSTAT!1 -> ENUM_IN_FSV_2091 NASA_USE_THERMOSTAT2 -> ENUM_IN_FSV_2092 Fixes #9
This commit is contained in:
@@ -21,6 +21,7 @@ class MessageProcessor:
|
||||
"""
|
||||
|
||||
_instance = None
|
||||
tmpdict = {}
|
||||
|
||||
def __new__(cls, *args, **kwargs):
|
||||
"""
|
||||
@@ -78,10 +79,11 @@ class MessageProcessor:
|
||||
raise MessageWarningException(argument=f"{msg.packet_payload}/{[hex(x) for x in msg.packet_payload]}", message=f"Value of {hexmsg} couldn't be determinate, skip Message {e}")
|
||||
self.protocolMessage(msg, msgname, msgvalue)
|
||||
else:
|
||||
packedval = int.from_bytes(msg.packet_payload, byteorder='big', signed=True)
|
||||
if self.config.LOGGING['messageNotFound']:
|
||||
logger.info(f"Message not Found in NASA repository: {hexmsg:<6} Type: {msg.packet_message_type} Payload: {msg.packet_payload}")
|
||||
logger.info(f"Message not Found in NASA repository: {hexmsg:<6} Type: {msg.packet_message_type} Payload: {msg.packet_payload} = {packedval}")
|
||||
else:
|
||||
logger.debug(f"Message not Found in NASA repository: {hexmsg:<6} Type: {msg.packet_message_type} Payload: {msg.packet_payload}")
|
||||
logger.debug(f"Message not Found in NASA repository: {hexmsg:<6} Type: {msg.packet_message_type} Payload: {msg.packet_payload} = {packedval}")
|
||||
|
||||
def protocolMessage(self, msg: NASAMessage, msgname, msgvalue):
|
||||
"""
|
||||
|
||||
Reference in New Issue