Feature/v0.2.0 (#7)

* heateroutput limit 0 - 15000 w

* heatoutput always positive

* ENUM_IN_FSV_2041 value 0c00 unknwon added

* recalculate crc6 checksum and check it

* skip exception to reduce logging

* NASAPacket and NASAMessage prepared for write mode
MQTT Auto Discovery changed single entitity to all entities
NASA Packet crc16 Checksum verificated

* - Changed MQTT Auto Discovery Config Message from single Entitiy to all Entities at ones, known devices are fully configured, not known empty (markt to delete)
- NASAPacket and NASAMessage are now bidirectional, can decode and encode Packets
- Added crc16 Checksum check for any Packet to reduce incorrect value changes
- Folling warnings moved to SkipInvalidPacketException and from warning to debug log level to reduce Logentries
  - Source Adress Class out of enum
  - Destination Adress Class out of enum
  - Checksum for package could not be validatet calculated
  - Message with structure type must have capacity of 1.

* NASA_OUTDOOR_HP as kw unit

* NASA Repository, measurements enums completed

* filter wifikit heartbeat

* process only packets from indoor or outdoor

* correct readme

* remove expire

* device discovery status

* new mqtt hass configuration approach

* added new measurements

* added new logging features from config


* NASA_EHSSENTINEL_TOTAL_COP added

* removed silentMode, added logging proccessedMessage

* loaded devices

* loaded devices counter fix

* only if retain true

* final 0.2.0 commit
This commit is contained in:
echoDaveD
2025-02-22 22:45:18 +01:00
committed by GitHub
parent cce625dabb
commit 48ef003f22
13 changed files with 1069 additions and 386 deletions

View File

@@ -2,7 +2,7 @@ import asyncio
import logging
import traceback
import yaml
from CustomLogger import logger, setSilent
from CustomLogger import logger
from EHSArguments import EHSArguments
from EHSConfig import EHSConfig
from EHSExceptions import MessageWarningException
@@ -53,7 +53,6 @@ class MessageProcessor:
if self._initialized:
return
self._initialized = True
logger.debug("init MessageProcessor")
self.config = EHSConfig()
self.args = EHSArguments()
self.mqtt = MQTTClient()
@@ -79,7 +78,10 @@ class MessageProcessor:
raise MessageWarningException(argument=f"{msg.packet_payload}/{[hex(x) for x in msg.packet_payload]}", message=f"Value of {hexmsg} couldn't be determinate, skip Message {e}")
self.protocolMessage(msg, msgname, msgvalue)
else:
logger.debug(f"Message not Found in NASA repository: {hexmsg:<6} Type: {msg.packet_message_type} Payload: {msg.packet_payload}")
if self.config.LOGGING['messageNotFound']:
logger.info(f"Message not Found in NASA repository: {hexmsg:<6} Type: {msg.packet_message_type} Payload: {msg.packet_payload}")
else:
logger.debug(f"Message not Found in NASA repository: {hexmsg:<6} Type: {msg.packet_message_type} Payload: {msg.packet_payload}")
def protocolMessage(self, msg: NASAMessage, msgname, msgvalue):
"""
@@ -98,7 +100,10 @@ class MessageProcessor:
- Calculates and processes derived values for specific message names.
"""
logger.info(f"Message number: {hex(msg.packet_message):<6} {msgname:<50} Type: {msg.packet_message_type} Payload: {msgvalue}")
if self.config.LOGGING['proccessedMessage']:
logger.info(f"Message number: {hex(msg.packet_message):<6} {msgname:<50} Type: {msg.packet_message_type} Payload: {msgvalue}")
else:
logger.debug(f"Message number: {hex(msg.packet_message):<6} {msgname:<50} Type: {msg.packet_message_type} Payload: {msgvalue}")
if self.config.GENERAL['protocolFile'] is not None:
with open(self.config.GENERAL['protocolFile'], "a") as protWriter:
@@ -110,14 +115,18 @@ class MessageProcessor:
if msgname in ['NASA_OUTDOOR_TW2_TEMP', 'NASA_OUTDOOR_TW1_TEMP', 'VAR_IN_FLOW_SENSOR_CALC']:
if all(k in self.NASA_VAL_STORE for k in ['NASA_OUTDOOR_TW2_TEMP', 'NASA_OUTDOOR_TW1_TEMP', 'VAR_IN_FLOW_SENSOR_CALC']):
self.protocolMessage(NASAMessage(packet_message=0x9999, packet_message_type=1),
"NASA_EHSSENTINEL_HEAT_OUTPUT",
round(
(
(self.NASA_VAL_STORE['NASA_OUTDOOR_TW2_TEMP'] - self.NASA_VAL_STORE['NASA_OUTDOOR_TW1_TEMP']) *
(self.NASA_VAL_STORE['VAR_IN_FLOW_SENSOR_CALC']/60)
* 4190
), 4))
value = round(
abs(
(self.NASA_VAL_STORE['NASA_OUTDOOR_TW2_TEMP'] - self.NASA_VAL_STORE['NASA_OUTDOOR_TW1_TEMP']) *
(self.NASA_VAL_STORE['VAR_IN_FLOW_SENSOR_CALC']/60)
* 4190
) , 4
)
if (value < 15000 and value > 0): # only if heater output between 0 und 15000 W
self.protocolMessage(NASAMessage(packet_message=0x9999, packet_message_type=1),
"NASA_EHSSENTINEL_HEAT_OUTPUT",
value
)
if msgname in ('NASA_EHSSENTINEL_HEAT_OUTPUT', 'NASA_OUTDOOR_CONTROL_WATTMETER_ALL_UNIT'):
if all(k in self.NASA_VAL_STORE for k in ['NASA_EHSSENTINEL_HEAT_OUTPUT', 'NASA_OUTDOOR_CONTROL_WATTMETER_ALL_UNIT']):
@@ -125,6 +134,13 @@ class MessageProcessor:
self.protocolMessage(NASAMessage(packet_message=0x9998, packet_message_type=1),
"NASA_EHSSENTINEL_COP",
round((self.NASA_VAL_STORE['NASA_EHSSENTINEL_HEAT_OUTPUT'] / self.NASA_VAL_STORE['NASA_OUTDOOR_CONTROL_WATTMETER_ALL_UNIT']/1000.), 3))
if msgname in ('NASA_OUTDOOR_CONTROL_WATTMETER_ALL_UNIT_ACCUM', 'LVAR_IN_TOTAL_GENERATED_POWER'):
if all(k in self.NASA_VAL_STORE for k in ['NASA_OUTDOOR_CONTROL_WATTMETER_ALL_UNIT_ACCUM', 'LVAR_IN_TOTAL_GENERATED_POWER']):
if (self.NASA_VAL_STORE['NASA_OUTDOOR_CONTROL_WATTMETER_ALL_UNIT_ACCUM'] > 0):
self.protocolMessage(NASAMessage(packet_message=0x9997, packet_message_type=1),
"NASA_EHSSENTINEL_TOTAL_COP",
round(self.NASA_VAL_STORE['LVAR_IN_TOTAL_GENERATED_POWER'] / self.NASA_VAL_STORE['NASA_OUTDOOR_CONTROL_WATTMETER_ALL_UNIT_ACCUM'], 3))
def search_nasa_table(self, address):
"""
@@ -157,7 +173,7 @@ class MessageProcessor:
try:
value = eval(arithmetic)
except Exception as e:
logger.warning(f"Arithmetic Function couldn't been applied, using raw value: arithmetic = {arithmetic} {e}")
logger.warning(f"Arithmetic Function couldn't been applied for Message {msgname}, using raw value: arithmetic = {arithmetic} {e}")
value = packed_value
else: